Most homes here run on LP gas
Bottled, tank or LP gas heats 62.6% of homes in Oliver County. Electricity is a distant second at 21.1%. A gas furnace paired with central air is still the setup most homes here are built around.
Takes about a minute. No obligation.
Bottled, tank or LP gas heats 62.6% of homes in Oliver County. Electricity is a distant second at 21.1%. A gas furnace paired with central air is still the setup most homes here are built around.
Add a heat pump here and the gas furnace usually stays, working as backup for the coldest stretches. The contractor sizing the job needs to know your current furnace and ductwork to set the switchover point correctly.

NOAA nClimDiv, 1991–2020 normals
Half the homes in Oliver County were built in 1976 or earlier, half in 1976 or later.
A heat pump sized to your square footage works the same either way.




Center sits in climate zone 6A, cold with winters that run long. Any split-system heat pump sold here new has to clear federal minimums set in 2023. That means 14.3 SEER2 for cooling and 7.5 HSPF2 for heating. The floor is the same whether the contractor is quoting a small unit or a large one, so it limits what can legally go into your home. Ask any contractor how the model they're proposing clears it. A federal tax credit may also apply to a qualifying heat pump, worth checking against your own tax situation before you decide.
A standard size and efficiency fit fine here. There's no local reason to go bigger or pricier.
Find a contractor
The old furnace doesn't necessarily go anywhere. If it's staying on as backup, it only has to fire on the coldest days instead of running the whole season, and that lighter duty can stretch its remaining life. If it's coming out, a tech checks the heat exchanger and the flue before anything gets disconnected, since gas equipment has to be decommissioned properly, not just unplugged. Old refrigerant lines usually can't be reused for a heat pump. The line set gets swapped along with the outdoor unit. Whatever gets hauled away, the thermostat wiring and the ductwork it leaves behind need to be checked for the new system, not just left as they were.
The compressor and coil sitting outside carry most of the price tag. A bigger compressor, one built to keep pulling heat from cold air without straining, costs more than a smaller one. So does a cabinet built to shed ice and keep running through rough weather.
If the ductwork can move the air a heat pump puts out and the electrical panel has room for the new circuit, the install goes faster. If the ducts need rework or the panel needs an upgrade to carry the load, that work gets added to the job before the heat pump itself goes in.
When you've got quotes in hand, ask what size each contractor landed on and how they got there. A real load calculation looks at your square footage, your windows, your insulation, and your ductwork together. If one number is just pulled from a chart matching tonnage to square feet, that's a red flag, not a shortcut. Ask what happens at the coldest point in winter. Does the heat pump keep working on its own, or does it hand off to the furnace, and at what temperature. Ask about the sound rating of the outdoor unit too, since some run quieter than others sitting right outside a window. And ask what's covered under warranty, especially the compressor, since that's the part most likely to fail and the most expensive to replace.
Installation day starts before anyone touches a wrench. The contractor walks the ductwork, checks the electrical panel, and confirms where the new line set will run between the indoor and outdoor units. Once that's settled, the old equipment comes out first if this is a replacement. The outdoor pad gets leveled or poured if it needs it, since the compressor has to sit flat and solid for the life of the unit. Running the refrigerant lines and electrical whip comes next, then the indoor coil ties into the existing ductwork or air handler. Before anyone calls it done, the system gets charged with refrigerant, tested in both heating and cooling mode, and checked for the right airflow across the coil. A heat pump that's wired but never tested under both modes is a callback waiting to happen.