Why winters here decide this
Your winters are the whole question. The overnight low here averages 6°F across December, January and February, and that number sits below the two marks that matter for a heat pump. Below 40°F a standard heat pump puts out less than its rated capacity. Below about 35°F it often needs backup heat to make up the difference. At 6°F average, most of your winter nights fall under both marks, not just the cold snaps.
Count the nights instead of the average and it gets clearer. About 190 nights a year here drop to freezing or below, out of roughly 275 nights in the nine months your heat runs. That is over half the heating season already below the point where a standard heat pump loses ground. About 40 nights a year reach 0°F or below, and a heat pump still has to make heat through those too.
This does not rule out a heat pump. Cold climate models exist for exactly this problem. To earn the ENERGY STAR Cold Climate label, a heat pump has to still produce 1.75 units of heat per unit of electricity at 5°F, and hold onto at least 70 percent of its 47°F capacity at that temperature, checked by outside testing, not the manufacturer's own numbers. A field test of prototype cold climate heat pumps over two winters found backup heat covered only a small share of the output between 0°F and 35°F, and the units rarely ran on backup alone even above 0°F. If you go with a heat pump here, that rating is what to ask for. A standard one, built to the federal minimum, is not built for your winter.