What the cold does to a heat pump here
Winter is the real question in Dickey County, because heat runs nine months a year here and cooling only three. Whatever you buy, it will spend most of its life heating your house, not cooling it.
A standard heat pump starts losing ground below 40°F, and by the time it's below about 35°F it often needs backup heat to keep up. The average overnight low here in December, January and February is 6°F. That's not a cold snap, that's the season average, and it sits well under both of those marks.
It gets more specific than that. About 180 nights a year here drop to freezing or below, more than half of all the nights in the nine months the heat runs. About 40 of those nights hit 0°F or below. On every single one of those 180 nights, a standard heat pump is operating past the point where its output falls short of the rating, and past the point where it typically leans on backup heat.
There is a version built for this. Heat pumps with the ENERGY STAR Cold Climate mark are tested to still produce at least 1.75 units of heat per unit of electricity at 5°F, and to hold onto at least 70 percent of their 47°F capacity at that same temperature. Field tests of prototype cold-climate heat pumps back this up: backup heat only covered a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. A standard heat pump was not built with this county's winter in mind. A cold-climate one was.