Why the cold here decides this
Winter is most of the year in Mountrail County. Heat runs ten months, September through June, and the overnight low averages 4°F across December, January and February. A standard heat pump starts falling behind before it gets anywhere near that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it usually needs backup heat to make up the difference. A winter night here averaging 4°F is not an edge case for a standard heat pump. It is the normal night.
About 200 nights a year here drop to freezing or below, over half the nights the heat runs at all. Of those, about 45 reach 0°F or colder. Every one of those 200-plus nights falls below both marks where a standard heat pump struggles, the 40°F output mark and the 35°F backup-heat mark. A furnace does not have this problem. It burns gas or propane and makes its full rated heat whether it is 30°F out or 10 below. Cold does not change what it delivers.
There is a version of a heat pump built for this. ENERGY STAR Cold Climate models are tested to still make at least 1.75 units of heat per unit of electricity at 5°F, and to hold onto at least 70 percent of their 47°F capacity at that same temperature. A two winter field test of prototype cold-climate units found backup heat covered only a small share of the total between 0°F and 35°F, and that running on backup alone was rare even above 0°F. A standard heat pump is a poor match for a place this cold. A cold-climate one is a different machine, and worth asking about by name if a heat pump is still on the table.