What the cold does to a heat pump here
Your winters decide this. The overnight low here averages 8°F across December, January and February, and that's an average, not the floor. About 195 nights a year drop to freezing or below, and 35 of those drop to 0°F or colder. A standard heat pump starts losing ground well before it gets that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it typically needs backup heat to make up the difference. Your average winter night is colder than both of those marks, and every single one of your 195 freezing nights is too.
That doesn't mean a heat pump quits. Cold climate models, the ones carrying the ENERGY STAR Cold Climate mark, are tested to hold at least 70 percent of their 47°F output at 5°F, and still make more than one and a half units of heat per unit of electricity at that temperature. Field tests of prototype cold climate units back this up: backup heat covered only a small share of the heat needed between 0°F and 35°F, and running on backup alone was rare even above 0°F. So the real choice in this county isn't heat pump against furnace in the abstract. It's a standard heat pump, which will lean on backup heat most of your winter, against a cold climate heat pump, which mostly won't.