Can a heat pump handle winter here
Benson County winters settle the question before cost ever comes up. The average overnight low across December, January and February is 1°F. A standard heat pump starts losing ground to its own rating once it is below 40°F outside, and by the time it is in the teens it is putting out a fraction of what it is rated for. On about 190 nights a year here, the temperature falls to 32°F or below. On about 50 of those nights, it falls to 0°F or below. Every one of those 190 nights sits below both marks where a standard heat pump struggles.
That does not rule out a heat pump. It rules out a standard one running alone. Below about 35°F a standard heat pump typically needs backup heat to keep up, and a county averaging 1°F in the dead of winter will call on that backup often. A heat pump built to the ENERGY STAR Cold Climate spec is a different machine: to earn that label it has to deliver at least 1.75 units of heat per unit of electricity at 5°F, and hold on to at least 70 percent of its 47°F capacity at that same temperature. Field tests of cold-climate heat pumps in occupied homes found backup heat carried only a small share of the load between 0°F and 35°F, and the home running on backup alone was rare even above 0°F. If a heat pump goes into this county, it has to be that cold-climate version, not the federal minimum unit the running-cost numbers above are built on.
The heating season here is also the long one. Homes run heat about nine months a year, September through May, and cooling just two, July and August. A furnace does nothing for those other three months. A heat pump heats and cools with the same equipment, which matters more in a place where the cold months outnumber the warm ones three to one.