Nine months of heat a year
Furnaces in Benson County run from September through May. That is most of the year asking the igniter, the blower motor and the heat exchanger to work, with only a short break in summer.
Takes about a minute. No obligation.
Furnaces in Benson County run from September through May. That is most of the year asking the igniter, the blower motor and the heat exchanger to work, with only a short break in summer.
Overnight lows average 1°F through December, January and February. A furnace has to run longer and hotter to hold the house, and that kind of load wears parts down faster than a mild winter would.
Most homes in Benson County heat with LP gas, 59.3% of them.
A furnace running on LP gas needs its burner and venting checked every year, not just a filter swap.




Half the homes in Benson County were built in 1972 or earlier. A furnace in a house that old may not be original, and nobody but the homeowner knows for sure how old the one running today actually is. That's the case for a yearly check rather than a guess. A tech can open the cabinet and tell you what shape the heat exchanger and igniter are in, and whether the unit is nearing the end of its life. Catching a cracked exchanger or a weak igniter early beats finding out when it fails on a cold night.
September through May is a long stretch to run on parts that haven't been looked at. Get the furnace checked now, while it's idle, so the igniter and heat exchanger are already sound before the first cold night calls on them.
Find a contractorA yearly check is how you keep tabs on a furnace whose history you don't fully know. Book it for the same month each year and let the tech log what they find in the cabinet each time. That log is what tells you whether the heat exchanger is holding up or starting to go, long before you'd ever hear it in how the house feels.
A dirty filter is the one thing worth checking without a tech. Pull it out and hold it up to a light. If you can't see through it, swap it. A clogged filter starves the burner of airflow and can crack a heat exchanger over time.
The blower motor, the burner and the heat exchanger are not something to open up and inspect on your own. Taking panels off without knowing what you're looking at can knock a wire loose or leave a door ajar that keeps the furnace from firing at all. Checking those parts is the tech's job, not yours.
A quick tune-up gets the furnace running and the tech out the door. A thorough one checks whether it should keep running the way it is. That means pulling the burner assembly to look at the flame pattern, not just glancing at it through a viewing port. It means checking amp draw on the blower motor against what the motor is rated for, not just confirming the fan comes on. The heat exchanger gets inspected for cracks or rust-through, not just a visual from arm's length with a flashlight. Flue venting gets checked for a solid connection and proper draft, since a loose joint there is a safety issue, not a performance one. If the tech is in and out in a few minutes with nothing written down, ask what they actually looked at.
A full tune-up starts before the burner ever fires. The tech checks gas pressure at the manifold against the rating plate, because too high or too low changes how clean the burner actually burns. The flame sensor gets cleaned or replaced if it's worn thin, since a weak signal there is what causes a furnace to shut off a few seconds after starting. Belts are rare on modern blowers, but the motor bearings and the wheel itself get checked for wobble or noise that points to wear. Wiring connections get snugged down, because a loose one can cause the board to misread a signal and shut the whole system down. Every safety switch, the limit switch, the pressure switch, the flame rollout switch, gets tested to confirm it will actually stop the furnace if something goes wrong. That last part is the one most people never think about, and it's the one that matters most.
