What the cold here does to a heat pump
Winter nights here average -1°F, and about 60 of them drop to 0°F or below. That matters because a standard heat pump starts losing heating capacity below 40°F and often needs backup heat below about 35°F. Here, every one of the roughly 200 nights a year at or below freezing falls below both marks.
That does not mean a heat pump stops working. It means it is not working at full strength for most of the nine months it would need to run, September through May. The furnace does not have this problem. It burns gas and makes its full rated heat whether it is 30°F outside or far colder.
A heat pump built to the ENERGY STAR Cold Climate spec is a different machine. To earn that label it has to make at least 1.75 units of heat for every unit of electricity at 5°F, and keep most of its 47°F capacity at that temperature. Field testing on prototype cold-climate units found backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. If a heat pump is the direction you want here, that is the spec to ask about, not the federal minimum.