Gas heats most homes here
Utility gas heats 51.4% of homes in Stark County, with electricity at 37.9% and propane at 5.2%. A furnace is still the default in most houses.
Takes about a minute. No obligation.
Utility gas heats 51.4% of homes in Stark County, with electricity at 37.9% and propane at 5.2%. A furnace is still the default in most houses.
Pairing a heat pump with an existing gas furnace, or replacing that furnace outright, means new refrigerant lines and controls that this home's gas system never needed. Worth asking a contractor what that setup looks like for your house.

NOAA nClimDiv, 1991–2020 normals
Heat here runs September through June, about ten months of the year.
August is the month to get a heat pump installed, before it has to carry the house.




Stark County is in climate zone 6A, a cold zone under the energy code. Any split-system heat pump installed here has to meet federal minimums of 14.3 SEER2 for cooling and 7.5 HSPF2 for heating. That rule narrows the field before you even start comparing brands. A contractor sizing a system for this county is working within that floor, not above or below it.
A new system here will work harder than most, every year. Size it right and don't buy on price alone.
Find a contractorWhen the old furnace or AC comes out, it's gone for good. A contractor disconnects the gas line or caps it, pulls the old refrigerant lines, and hauls the equipment away. If the house is keeping a gas furnace and adding a heat pump alongside it, the furnace stays put. The new system ties into the same ductwork and shares the existing blower rather than replacing it. That setup switches between the heat pump and the furnace on its own, running on the heat pump until it can't keep up, then handing off to gas. A straight replacement is simpler. Old equipment comes out, new refrigerant lines get run, a new pad or mounting bracket goes in, and the thermostat gets swapped for one built to run a heat pump's reversing valve. Either way, the old system doesn't get resold or reused anywhere else. Once it's disconnected, it's scrapped.
The outdoor unit and the indoor coil have to be matched for the system to run at its rated efficiency. A bigger house, or one with a tricky spot to mount the outdoor unit, pushes toward a larger unit or extra labor to run lines around obstacles. Cold-climate heat pumps use a compressor built to keep producing heat at low outdoor temperatures, and that compressor costs more than a standard one.
Heat pumps move more air at a lower temperature than a gas furnace does, so they ask more of the ducts carrying that air. Ducts that are undersized or leaky force a contractor to either rework them or accept a system that struggles to deliver what it's rated for. Checking the ductwork before the quote is where a straight price and a price with surprises in it start to split apart.
Ask what happens on the coldest night of the year, not the mildest one. Every heat pump has a balance point, the outdoor temperature where it stops keeping up on its own and leans on backup heat. Below that point, a unit without strong cold-weather performance runs backup strip heat or a gas furnace more than people expect, and that changes what the system actually costs to run. Ask for the balance point in writing, not a verbal estimate. Ask how sound level compares to what's already outside, since the outdoor unit runs through the winter, not just summer. And ask what the warranty covers on the compressor versus the labor to replace it, because those are often sold separately even when they're quoted together.
Installation day starts with the old equipment coming out, and that takes longer than people expect. The crew disconnects refrigerant lines, drains what's left, and if a furnace is leaving too, caps the gas line. Setting the new outdoor unit is its own job, since it needs a level pad and enough clearance on all sides to pull air through the coil. Indoors, the air handler or coil gets tied into the existing ducts, and the line set connecting outdoor to indoor gets brazed, pressure tested, then pulled into a vacuum to clear out moisture and air before any refrigerant goes in. That vacuum test matters more than almost anything else done that day. A system charged with air or moisture still trapped inside will run, but it won't hit its rated efficiency and the compressor wears faster than it should. Expect the crew to spend real time on that step even though there's nothing to watch.