Gas heats most homes here
Utility gas heats 63.6% of occupied homes in Burleigh County. Most furnaces around Bismarck run on it, and electric heat accounts for about a quarter of homes.
Takes about a minute. No obligation.
Utility gas heats 63.6% of occupied homes in Burleigh County. Most furnaces around Bismarck run on it, and electric heat accounts for about a quarter of homes.
Installing a heat pump here usually means pairing it with the existing gas furnace as backup for the coldest stretches, rather than replacing one fuel with another. A contractor can walk through whether a dual system or a cold-climate heat pump fits your setup.

NOAA nClimDiv, 1991–2020 normals
The rating on a heat pump tells you how much heat it moves per unit of power, not how warm your house will feel at the coldest part of winter.
A unit with a higher rating costs less to run most months, but the number on the label is measured at mild temperatures, so ask what it can still deliver when it's cold out.




Burleigh County falls under zone 6A, a cold and fairly humid climate under the 2021 energy code. Any split-system heat pump installed here has to hit federal minimums of 14.3 SEER2 for cooling and 7.5 HSPF2 for heating. Those numbers set the floor, not the ceiling, so plenty of equipment on the market clears them by a wide margin. A heat pump that only meets the minimum will cost more to run through a North Dakota winter than one built for colder climates, even though both are legal to install. Ask what HSPF2 rating a unit carries before you settle on it, not just whether it passes.
A new system here will work harder than most, every year. Size it right and don't buy on price alone.
Find a contractorA heat pump installation isn't priced off the unit alone. Sizing drives most of it. A contractor has to run a load calculation on the house, the room sizes, the windows, the insulation, before quoting anything, and a system sized wrong either costs more up front than it needs to or fails to keep up and costs more to run for as long as it's installed. Beyond the equipment, a lot of the price is in what has to change to put it in. Ductwork built for a furnace doesn't always move enough air for a heat pump, so it may need modifying. The electrical panel has to supply enough power for the unit, and older panels sometimes need upgrading first. Where the outdoor unit sits matters too, since it needs clearance for airflow and drainage, and running new line sets or wiring to reach that spot adds labor. A cold-climate heat pump, built to keep producing heat at low outdoor temperatures, costs more than a standard model, but it also keeps the backup heat source from carrying the load every time the temperature drops. None of that shows up in a quote that only lists the equipment.
A furnace or AC condenser coming out has to be disconnected properly. Gas lines get capped, electrical disconnects get pulled, and refrigerant in an old AC system has to be recovered rather than vented, since releasing it is against the law. A contractor handles all of that as part of swapping it out.
If a heat pump goes in alongside an existing gas furnace instead of replacing it outright, the furnace doesn't get removed at all. It gets wired in as backup heat, kicking on only when outdoor temperatures drop below what the heat pump can handle efficiently on its own.
Sizing a heat pump starts with a load calculation, not a tape measure around the old unit. A contractor adds up the square footage, but also the windows, the insulation, the ceiling height, and how much sun hits the walls, because all of that changes how fast a house loses heat or gains it. Skip that step and guess off the furnace it's replacing, and the new system inherits whatever was wrong with the sizing the first time around. Too big and it short cycles, kicking on, satisfying the thermostat fast, then shutting off again before it's run long enough to dehumidify the air or settle into steady output. Too small and it runs constantly without catching up, leaning on backup heat far more than it should. Either way the equipment wears faster and the house never feels quite right, even though the unit itself might be a good one.
Installation day starts before anyone touches the old equipment. A contractor shuts down power and gas to the system coming out, recovers the refrigerant, and disconnects the lines before anything gets lifted out. The indoor coil and outdoor unit usually come out and go in the same day, but the work around them takes longer than the swap itself. Line sets get run between the new indoor and outdoor units, and if the old ones aren't rated for the new refrigerant, they get replaced rather than reused. The electrical hookup gets tested, the condensate drain gets checked for a proper slope, and the whole system gets charged with refrigerant to the manufacturer's spec before it ever runs. Once it's running, a contractor checks airflow at the vents and lets the system cycle to make sure it's holding temperature the way it's supposed to before calling the job done.