What winter here does to a heat pump
Winter here is the whole question. The heat runs nine months a year, September through May, and the overnight low for December, January and February averages 1°F. That number sits well below the two marks that matter for a heat pump. Below 40°F its heat output falls short of what it's rated for. Below about 35°F it often needs backup heat to make up the difference. At 1°F average, you're past both marks on most winter nights, not just the cold snaps.
About 195 nights a year here drop to freezing or below, over half of the nights the heat runs. Of those, about 55 reach 0°F or below. So the question isn't whether a heat pump in Pierce County will lean on backup heat sometimes. It's that it will lean on it on more than half the nights of a typical winter, and lean on it hard on close to a third of those.
That doesn't mean a heat pump can't keep a house warm here. A cold climate model, the kind certified to make at least 1.75 units of heat per unit of electricity at 5°F and hold 70 percent of its warm-weather output at that same temperature, is built for exactly this. Field testing on prototype cold-climate units found backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. A standard heat pump, built to the federal minimum, is a different machine. It's the one that struggles once the temperature drops toward 1°F.