What the cold here does to a heat pump
Winters here decide this. The overnight low averages 2°F across December, January and February, and that's below the two marks that matter for a heat pump. Below 40°F its heat output falls short of what it's rated for. Below about 35°F it often needs backup heat to make up the difference. Here, every one of the roughly 200 nights a year at or below freezing is below both marks.
That doesn't mean a heat pump can't heat your house. A heat pump carrying the ENERGY STAR Cold Climate label is tested to hold at least 1.75 units of heat for every unit of electricity at 5°F, and to keep at least 70 percent of its 47°F capacity at that same 5°F. A standard heat pump isn't built or tested to that mark. If you're set on a heat pump here, that label is what separates one that can carry your house through January from one that's working past its limit.
Field testing on cold-climate heat pumps in occupied homes over two winters found backup heat carried only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. About 50 nights a year here reach 0°F or below. Most of the roughly 200 nights at or below freezing sit above that mark, in the range that same testing covered.