What the cold does to a heat pump here
Winter nights in Eddy County average 2°F, and about 190 nights a year drop to freezing or below. The heat runs nine months here, September through May, so that cold is most of the job, not an edge case.
A standard heat pump starts losing ground well before it gets anywhere near 2°F. Below 40°F it already puts out less heat than its rating says. Below about 35°F it typically needs backup heat to keep up. Eddy County's average winter low sits under both marks, and every single one of those 190 freezing nights does too. A standard heat pump in this county is not working at its rated output on a typical winter night. It is working below both marks where it starts falling behind.
Cold climate heat pumps are built for this instead of against it. To earn the ENERGY STAR cold climate label, a unit has to keep making at least 1.75 units of heat per unit of electricity at 5°F, and hold onto at least 70 percent of its 47°F capacity at that temperature. Field testing on prototype cold climate units backs this up: across two winters in occupied homes, backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. About 50 nights a year here reach 0°F or below, the rest stay above it. That is the range a cold climate unit is built to handle.