What the cold does to a heat pump here
Winter is the whole question in Ward County. Heat runs nine months a year, September through May, and the overnight low averages 5°F across December, January and February. That number matters more than any other on this page, because it sits well below the two marks that define how a standard heat pump behaves in the cold.
A standard heat pump starts falling short of its rated heat output once it is below 40°F outside. Below about 35°F, it often needs backup heat to keep up. Here, about 180 nights a year drop to freezing or below, and every single one of those nights is below both marks. The average winter night does not brush up against the point where a heat pump struggles. It sits past it.
About 40 nights a year here reach 0°F or below. A standard heat pump has little left to give at that temperature. An ENERGY STAR Cold Climate model is built for this: to earn that label it has to deliver real heat at 5°F and hold onto most of its capacity there, tested by someone other than the company selling it. That rating is the one that matters for this county, not the federal minimum. A two-winter field test of cold-climate heat pumps in real homes backed this up: backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. A furnace never has this problem. It is sized for the coldest night and makes the same heat on that night as on any other.