Winters here are the whole question
Your furnace runs nine months a year in LaMoure County, September through May. The overnight low averages 5°F across December, January and February, and it drops to freezing or below on about 180 nights a year. Forty of those nights hit 0°F or colder. Whatever heats your house here has to do it on nights like that, not just the mild ones.
A standard heat pump starts losing ground before it gets anywhere near 5°F. Its heat output falls short of its rating once it's below 40°F outside, and below about 35°F it typically needs backup heat to keep up. Here, every single one of those 180 freezing nights falls under both marks. That's not an edge case for this county. That's most of the winter.
This is why the running-cost number for a heat pump only tells you so much. The $1.53 per 100,000 Btu figured above assumes the heat pump is covering the load on its own, with nothing added for backup heat on the nights it can't. In LaMoure County, there are a lot of those nights.
There is hardware built for this. A heat pump carrying the ENERGY STAR Cold Climate label has to prove, under third-party testing, that it still makes at least 1.75 units of heat for every unit of electricity at 5°F, and holds onto at least 70 percent of its 47°F capacity at that same temperature. That is your average winter low, not an extreme for this county. A standard heat pump was never tested to do that. A cold-climate one was built to.