What 5 degrees does to a heat pump
Your winter low here averages 5°F, and that number is most of this decision. A standard heat pump starts losing ground below 40°F. Below about 35°F it usually needs backup heat to carry the house. Five degrees sits under both marks, not near them, under them. On an average winter night here, a standard heat pump is already reaching for backup heat to keep up.
That is not a cold snap, it is the season. About 185 nights a year here hit freezing or below, over half the nine months your heat runs. About 40 of those nights drop to 0°F or colder. A standard heat pump spends most of the winter here below the point where it puts out its full rated heat.
A gas furnace does not have this problem. It burns gas to make heat, so it makes the same heat on a 5°F night as it does on a 30°F one. In a county where the average low sits at 5°F across December, January and February, that difference matters every night, not just the worst ones.
There is a version of a heat pump built for exactly this. To carry the ENERGY STAR Cold Climate label, a heat pump has to prove it still makes 1.75 units of heat for every unit of electricity at 5°F, and keep at least 70 percent of its warm-weather capacity at that temperature, checked by outside testing. In field tests of these units, backup heat covered only a small share of the heat needed between 0°F and 35°F, and running on backup alone was rare even at 0°F. That is a different machine than the standard one behind the cost numbers above.