Why winter here decides this
Your winter low averages 9°F, and a standard heat pump starts losing ground well above that. Below 40°F it puts out less heat than its rating says. Below about 35°F it usually needs backup heat to make up the difference. Nine degrees is under both marks, and so is almost every night from September through June.
Over half the nights in the heating season here, about 190 of roughly 305, drop to freezing or below. On every one of those nights a standard heat pump is working below the point where it heats at full strength. About 30 nights a year reach 0°F or colder, and that is where a plain heat pump leans hardest on backup heat to keep the house warm.
A furnace does not have this problem. It burns gas, makes heat, and the outdoor temperature does not change how much it makes. At 9°F or at negative 20°F, the output is the same.
There is a version of a heat pump built for this. One certified as an ENERGY STAR Cold Climate model has to produce real heat at 5°F, at least 1.75 units of heat per unit of electricity, and hold onto 70 percent of its warm-weather capacity at that temperature, checked by outside testing. A field test of prototypes like these over two winters found backup heat covered only a small share of the load between 0°F and 35°F, and the units rarely ran on backup alone even at 0°F. That is a different machine than the standard one the running-cost band is priced on, and it is worth asking any contractor you talk to whether the heat pump they are quoting carries that rating.