What the cold here does to a heat pump
Winter nights in Rolette County average 0°F in December, January and February. That is not a rare dip. It happens about 60 nights a year, and another 145 nights drop somewhere between 0°F and freezing. Heat runs here about ten months, September through June, so the machine you pick has to work through all of that, not just the mild stretches.
A standard heat pump starts losing ground before it even gets near 0°F. Below 40°F its heating output falls under its rated capacity. Below about 35°F it typically needs backup heat to keep up. Every single night here that drops to freezing or below, about 205 of them a year, is past both of those marks. The average winter low of 0°F is well past them too.
That does not mean a heat pump quits. ENERGY STAR's Cold Climate models are built and tested to still produce real heat at 5°F, at least 1.75 units of heat per unit of electricity, while holding onto most of their 47°F capacity. Field tests of these cold-climate units in occupied homes found backup heat carried only a small part of the load between 0°F and 35°F, and running on backup alone was rare even at 0°F. So the newer equipment handles this climate better than the standard-efficiency numbers suggest. But it still leans on a backup heat source on the coldest nights, and in Rolette County those nights are common, not occasional.